MAIN AND SPECIAL AIR COOLER, REQUIREMENTS 4

 

Purpose

  • Main air cooler are intended for air processing in rooms.

  • Special air cooler are intended for air cooling used in processing procedure.

  • In main and special air cooler as a coolant can be used both fresh and sea water.

 

 

Technical characteristics

 

Type

Codes

Air flow,

 m3/h

 

Water flow,

kg/h

Cooling capacity,

 W

Weight,

 kg

-2,5 250 300 1600 32
-6,3 630 870 4800 63 
-10 1000 1450 7700 79 
-16 1600 2200 12000 105 
-25 2500 3500 19700 155
-40 4000 6500 31000 195
-63 6300 7800 52000 336 
-2,5 * 250 3450 23000 52
-6,3 * 630 6000 54500 110 

 * Input air temperature up to 250


 

 

AUTOMATED DC - WATERCOOLED MACHINE -0,1, REQIREMENTS 4

 

Purpose: cooling of seawater or fresh water for air conditioning systems.


Features:

  1. Frequency drive regulation

  2. Heat exchange apparatus and frame are made of corrosion resistant titanium alloys.

  3. Minimum in own class of weight and size characteristics.

 

Technical characteristics

Type of equipment

Cooling capacity,

W

Cooled

water

Water flow,

kg/h

Air flow,

m3/h 

 

Consumption power,

W

Automated watercooled machine

-0,1

100

sea

25000

-

36,5

 

 

 

 

 

 

DC - COOLING PLANT -1,6  WITH FREQUENCY DRIVE REGULATION, REQUIREMENTS 4

 

Purpose: to maintain the storage temperature of products in the negative and the positive stores of storage rooms (minus 9C and plus 3C). 

Technical characteristics

Type of equipment

Cooling capacity,

W

Cooled

 water

Water

flow,

kg/h

Air

flow, m3/h  

Consumption

power, W

Cooling plant for

provision storage rooms

-1,6

1,6

1000

-

1,5

 

 

 

 

SUMMER AC - CONDITIONER, REQUIREMENTS 4

 

Purpose: for local processing of indoor air, cooling of separate units.

 

Technical characteristics

 

Type Codes

Air flow,

m3/h

Water flow,

kg/h

Water temperature,

Cooling capacity,

W

Hydraulic resistance,

no more,P

-10

1000

1000

7

3900

20

-25

2500

3000

7

12000

30

-40

4000

7500

7

20000

49

 

 

Coolant: fresh water.

 

 

SUMMER DC - CONDITIONER, REQUIREMENTS 4

 

Purpose: local cooling of units.

 

Technical characteristics

 

Type Codes

Air flow,

m3/h

Water flow,

kg/h

Water temperature,

Cooling capacity,

W

Hydraulic resistance,

no more, P

-16

1600

1800

28

4300

49

-25

2500

4000

28

6700

49

 

Coolant: sea or fresh water.

 

 

 

SUMMER DC - CONDITIONER, REQUIREMENTS 2

 

Purpose: local cooling of units.

 

Technical characteristics

 

Type Codes

Air flow,

m3/h

Water flow,

kg/h

Water temperature,

Cooling capacity,

 W

Hydraulic resistance,

no more, P

-10

1000

1000

28

2700

49

-16

1600

1800

28

4300

49

-25

2500

4000

28

6700

49

-40

3500

7500

28

10700

49

 

 

Coolant: sea or fresh water .

 

 

 

CENTRAL AC - AIR CONDITIONERS, REQUIREMENTS 4

 

Purpose: cooling/ heat of air, maintain of desired climatic conditions of living and instrumentation compartments groups.

 

Technical characteristics

 

Type Codes

Air flow,

m3/h

Manometric pressure,

Pa

Output air temperature,

Cooling capacity,

W

Heating capacity,

W

-6,3/16

630

1600

14

3900

-

-10/10

1000

1000

14

5200

-

-16/10

1600

1000

14

8200

-

-16/16

1600

1600

14

8200

-

-25/10

2500

1000

14

13800

-

-25/16

2500

1600

14

13800

-

-10/10

1000

1000

14

5200

7000

-16/16

1600

1600

14

8200

8500

-25/16

1000

1000

14

13800

13000

 

Electric power: AC 380 V, 50 Hz.

 

 

AUTOMATED SPECIAL AC - CONDITIONER -3,0, REQUIREMNTS 4

 

Purpose: maintain of desired heat humidity indoor conditions.

 

Technical characteristics

 

Type Codes

Cooling capacity

in cooling mode,

W

Cooled

water

Water flow,

kg/h

Air flow,

m3/h

Consumption power

in cooling mode,

W

Consumption power

in dehydration mode,

W

Automated special conditioner

 -3,0

2,4

fresh

800

300

0,9

2,8

 

 

 

AC - UNIT OF HOT FILTRATION OF AIR -2,5, REQUIREMENTS 4

 

Purpose: catalytical purification of air pollutant of caboose and smoking rooms of ships.

 

Technical characteristics

 

Type Codes

Cooling capacity,

W

Cooled water

Water consumption,

kg/h

Air flow,

m3/h

Consumption power,

W

Unit of hot filtration of air

-2,5

-

fresh

300

250

9,0

 

 

 

AUTOMATED AC - CONDITIONER -12 AND -24, REQUIREMNTS 2

 

Purpose: to maintain comfortable climatic indoor conditions.

 

Technical characteristics

 

Type Codes

Cooling capacity,

W

Cooled water

Water flow,

kg/h

Air flow,

m3/h

Consumption power,

W

Automated conditioner -12

14

sea

4000

1500

7/14,5**

Automated conditioner -24

25

sea

8000

3000

14/22,6**

 

** in heating mode

 

 

 

AUTOMATED DC CONDITIONER -12  WITH INTEGRAL FAN, REQUIREMENTS 2

 

Purpose: cooling and ventilation of indoor recirculation air, providing and automatic maintain of comfortable climatic indoor conditions in submarines.

 

Technical characteristics

 

Type Codes

Cooling capacity,

W

Cooled water

Water flow,

kg/h

Air flow,

m3/h

Manometric pressure,

P

Output air temperature,

Consumption power,

W

-12

17000

sea

4000

2500

600

15

8800

 

 

Notice: products are made on request.

Developed by: RayStudio
Microcryogenic equipment
Equipment for liquefied natural gas (methane)
Cryogenic equipment
Integrated natural gas supply system
Compressed natural gas equipment
Optional equipment
Climatic and cooling equipment for ships and boats
Air - conditioners of special purpose
Shut-off regulating valves for liquids and gases
Compressor equipment
Booster-compressor
Oxygen filler
Nitrogen filler